Experience the Power of Predictive HPE Nimble Storage All Flash Arrays combine a flash-efficient architecture with HPE InfoSight predictive analytics to achieve fast, reliable access to data and 99.9999% guaranteed availability. Radically simple to deploy and use, the arrays are cloud-ready – providing data mobility to the cloud through HPE Cloud Volumes. Your storage investment made today will support you well into the future, thanks to our technology and business-model innovations. HPE Nimble Storage All Flash Arrays include all-inclusive licensing, easy upgrades, and flexible payment options – while also being future-proofed for new technologies, such as NVMe and SCM. What’s new Now HPE Nimble Storage All Flash Arrays are NEBS certified. A new all-flash array platform that is up to 65% faster and twice the scalability of previous all-flash arrays. HPE Nimble Storage All Flash Arrays are guaranteed provide more effective capacity per terabyte of raw storage than competitive all-flash arrays2. The new platform is future-proofed with an architecture for NVMe and Storage Class Memory (SCM). The arrays are designed to be upgraded with SCM for greater performance in the future. These all-flash arrays reflect Hewlett Packard Enterprise commitment to deliver business value today and tomorrow as demonstrated by our timeless storage.
HPE Nimble Storage All Flash Array models |
||||||
AF-Series Arrays |
AF20Q |
AF20 |
AF40 |
AF60 |
AF80 |
Scale-out1 4X AF80 |
Raw capacity (TB/TiB)2, 5 |
6–46/ 5-42 |
11–46/ 10-42 |
11-184/ 10-167 |
11–553/ 10-502 |
23-1106/ 21-1005 |
44232/ 4023 |
Usable capacity (TB/TiB)2 |
3-25/ 2–23 |
8-33/ 7-30 |
8–136/ 7–124 |
8–407/ 7–370 |
17-815/ 15-741 |
3260/ 2965 |
Effective capacity (TB/TiB)2, 3 |
14–128/ 13–116 |
40–168/ 36–153 |
40–682/ 36–620 |
40–2037/ 36–1853 |
82-4075/ 75-3706 |
16303/ 14827 |
Max. # of expansion shelves |
1 |
1 |
1 |
2 |
2 |
8 |
RAID level Triple+ Parity |
||||||
Onboard iSCSI/Mgmt 1Gb /10Gb ports per array4,6 |
4 |
4 |
4 |
4 |
4 |
16 |
Optional iSCSI 1 Gb ports per array6 |
4, 8, 12, 16 |
4, 8, 12, 16 |
4, 8, 12, 16, 20, 24 |
4, 8, 12, 16, 20, 24 |
4, 8, 12, 16, 20, 24 |
96 |
Optional iSCSI 10 Gb ports per array6 |
4, 8, 12, 16 |
4, 8, 12, 16 |
4, 8, 12, 16, 20, 24 |
4, 8, 12, 16, 20, 24 |
4, 8, 12, 16, 20, 24 |
96 |
Optional iSCSI 25 Gb ports per array6 |
4, 8 |
4, 8 |
4, 8, 12 |
4, 8, 12 |
4, 8, 12 |
48 |
Optional FC 16 Gb (8 Gb) ports per array6 |
4, 8, 12, 16 |
4, 8, 12, 16 |
4, 8, 12, 16, 20, 24 |
4, 8, 12, 16, 20, 24 |
4, 8, 12, 16, 20, 24 |
96 |
Optional FC 32 Gb (16 Gb) ports per array6 |
4, 8 |
4, 8 |
4, 8, 12 |
4, 8, 12 |
4, 8, 12 |
48 |
Max. power requirement (watts/kVA) |
600/0.667 |
650/0.722 |
800/0.889 |
850/0.944 |
1200/1.333 |
4800/5.332 |
Thermal (BTU) |
1968 |
2132 |
2624 |
2788 |
3936 |
15744 |